Yaskawa MP940 Reference Manual User Manual

Page 440

Advertising
background image

MotionSuite™ MP940 Machine Controller Reference Manual

Position Control

11-43

If no Motion Commands are Used

If motion commands are not used, the speed reference selection flag is
disabled and the speed-related parameters have the meanings shown in the
following table.

If Motion Commands are Used

If motion commands are used, the speed-related parameters differ in
accordance with the speed reference selection (bit 13 of OWC001).

Parameter No.

Name

Content

Bit 3 of OWC001

Speed Reference Selection

Disabled

OWC00A

Approach Speed Setting

Designate as a percentage of the rated speed.

OWC00B

Creep Speed Setting

Designate as a percentage of the rated speed.

OWC015

Speed Reference Setting

Designates the fast feed speed as a percentage of the
rated speed.

OLC022

Fast Feed Speed

Disabled

OWC02C

Override

Disabled

Bit 13 of

OWC001

Parameter

Number

Name

Content

0

OWC00A

Approach Speed Setting

Designated in command units.

OWC00B

Creep Speed Setting

Designated in command units.

OWC015

Speed Reference Setting

Disabled

OWC022

Fast Feed Speed

Designated in command units.

OWC02C

Override

Enabled

1

OWC00A

Approach Speed Setting

Designated as a percentage of the rated
speed.

OWC00B

Creep Speed Setting

Designate as a percentage of the rated
speed.

OWC015

Speed Reference Setting

Designates the fast feed speed as a
percentage of the rated speed.

OWC022

Fast Feed Speed

Disabled

OWC02C

Override

Enabled

Advertising