Run command setting (svruncmd) – Yaskawa MP940 Reference Manual User Manual

Page 222

Advertising
background image

Parameter Details

MotionSuite™ MP940 Machine Controller Reference Manual

6-22

Run Command Setting (SVRUNCMD)

Number

Register

Number

Bit Name

Content

Default

Value

2

OWC001 Sets the operation modes necessary for signal output from the module to the

SGDH as well as motion control.The bit structure is shown below.

Bit 0

Servo ON
(RUN) (DO0)

This is used as a servo ON signal for the drive. 1 is output
from DO0 when SVCRDY (IBC0007) is ON and this bit is
1.

0

Bit 1

P-CON

Speed Loop P/PI Switching

0

Bit 2

G-SEL

Gain Switching

0

Bit 3

P-CL

Forward External Torque Limit Input

0

Bit 4

N-CL

Reverse External Torque Limit Input

0

Bit 5

ZCLAMP

Zero Clamp Input

0

Bit 6

PHSCANSEL Phase Control Mode Synchronous Scan Selection

0: H Scan; 1: S Scan

0

Bit 7

PSCANSEL

position control Mode
Control Loop Synchronous Scan Selection
0: H Scan; 1: S Scan

1

Bit 8

ACCSEL

Position Control Mode
Selection of Accel/Decel Function Use in Simple Position-
ing
0:Used 1:Unused

0

Bit 9

SEGSEL

Position Control Mode Segment Assignment Function Use
Selection

0:Used 1:Unused

0

Bit 10

Unused

Bit 11

Unused

Advertising