Parameter Details

MotionSuite™ MP940 Machine Controller Reference Manual

6-36

34

Motion
Command
Options

Bit 14

Position Buffer
Write-in
(BUF_W)

The data set in position buffer write-in
data (OLC03A) is stored in the position
buffer set in the position buffer access
number (OLC038) as absolute position
data.

0

Bit 15

Position Buffer
Read-out
(BUF_R)

This reads out data from a position buffer
designated in the position buffer access
number (OLC038), and stores it in posi-
tion buffer read-out data (ILC028). This is
used when verifying position data stored
in the position buffer.
Be aware that 2 scans are required from
the time that read-out is commanded until
the data is stored in position buffer read-
out data (ILC028).

0

35

Feed Speed

OLC022

0 ~ 2

31-1

Set the fast feed speed in 10n command
units/min. (n: dumber of decimal places)
when the speed reference selection
(OBC001D) is set to 0.
When displayed by setting unit:
Pulse Unit Time: 1 = 1000 pulse/min.
When unit is mm: 1 = 1mm/min.
deg Units: 1 = 1deg/min.
Inch Units: F 18>
1 = 1inch/min.
Used when a motion command
(OWC020) is used in the position control
mode.

0

37

External
Positioning Move
Distance

OLC024

-2

31

~ 2

31-1

Sets the distance from where the latch
signal is input (external positioning signal)
to stoppage during external positioning
(EX_POSING).

0

Used when a motion command (OWC020) is used
in position control mode.

39

Stopping
Distance

OLC026

-2

31

~ 2

31-1

Used as a system. Do not use this param-
eter.

0

Other Command/Mode Settings (Continued)

Number

Name

Register

Number

Setting Range

Content

Default

Value

External Positioning

Run Distance

v

t

Latch

Signal