Function library

17.2

System blocks

1006

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

bDone

BOOL

"Read/Write request successfully completed" status signal

• The output is automatically reset to FALSE if a new request is activated via

bExecute or the cycle time (C01091) expires.

TRUE Read/Write request successfully completed.

FALSE The FALSE status can have the following meanings:

1.There is no active read/write request.

2.The read/write request has not been completed yet.

3.An error has occurred (if bFail = TRUE).

bFail

BOOL

"Error" status

TRUE An error has occurred (group signal).

• See display parameter (C01092) for details.

wOutHWord

wOutLWord

WORD

Value which was read (DataHigh/DataLow portion) after read request

Parameter

Possible settings

Info

C01090/1...3

(from version 06.00.00)

0,000

16000,000 Parameter to be read or written.

• For a setting of "0,000", inputs

wParIndex and wParSubindex are

effective for addressing purposes

instead.

• Lenze setting: 0.000

Format:

<Code number>,<subcode number>

C01091/1...3

Cycle time

• Subcode 1 = LS_ParReadWrite_1

Subcode 2 = LS_ParReadWrite_2

Subcode 3 = LS_ParReadWrite_3

• Lenze setting: 0

0 One-time reading/writing at

bExecute in case of a FALSE/TRUE

edge

Cyclic reading/writing:

20 20 ms
50 50 ms

100 100 ms
200 200 ms
500 500 ms

1000 1 s
2000 2 s
5000 5 s

10000 10 s