2 terminals 2, Terminals 2, 7technology applications – Lenze 8400 StateLine User Manual
Page 341
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
341
7
Technology applications
7.3
TA "actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.2
Terminals 2
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X4/RFR
LA_NCtrl.bFailReset
X3/A1U
LA_NCtrl.nAuxSetValue_a *
X4/DI1
LA_NCtrl.bJogSpeed1
X3/A1I
-
X4/DI2
LA_NCtrl.bJogSpeed2
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X4/DI3
LA_NCtrl.bSetQuickstop
* 10 V ≡ 100 % reference speed (
X4/DI4
LA_NCtrl.bSetSpeedCcw
X4/DO1
LA_NCtrl.bDriveReady
+
=
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
COM
NC
NO
X101
CG
C
L
CH
X1
Controller enable / reset error
External
supply
24 V DC
Fixed setpoint 1/3
Fixed setpoint 2/3
Change of direction of rotation
Quickstop
DriveReady
Actual speed value
DriveFail
Speed mode:
Torque mode:
Speed setpoint
Torque setpoint