1 activate & control motor potentiometer, Activate & control motor potentiometer, 17 function library – Lenze 8400 StateLine User Manual

Page 946

Advertising
background image

17

Function library

17.1

Function blocks

946

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.23.1 Activate & control motor potentiometer

When bInAct is set to FALSE, the motor potentiometer is activated.

• The currently active function depends on the current output signal nOut_a, the limit values set

and the control signals at bUp and bDown.

• When the nOut_a output signal is outside the limits set, the output signal runs to the next limit

with the Ti times set. This process is independent of the control signals at bUp and bDown.

• When the nOut_a output signal is inside the limits set, the output signal changes according to

the control signals at bUp and bDown.

[17-11] Example: Control of the motor potentiometer

nOut_a

t

t

TRUE

FALSE

bUp

t

TRUE

FALSE

bDown

nHighLimit

nLowLimit

0

wTir

wTir

wTif

wTir

bUp

bDown

bInact

Function

FALSE

FALSE

FALSE

The nOut_a output signal remains unchanged.

TRUE

FALSE

The nOut_a output signal runs to its upper limit value (nHighLimit).

FALSE

TRUE

The nOut_a output signal runs to its lower limit value (nLowLimit).

TRUE

TRUE

The nOut_a output signal remains unchanged.

-

-

TRUE

The motor potentiometer function is deactivated. The nOut_a

output signal responds according to the function selected via

Function.

Advertising