5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 214

Advertising
background image

5

Motor control (MCTRL)

5.9

Parameterisable additional functions

214

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Explanation of the automatic DC-injection braking function by means of two examples

[5-22] Example 1: Auto-GSB signal characteristic during V/f operation without speed feedback

[5-23] Example 2: Auto-GSB signal characteristic during V/f operation with speed feedback

The motor rotates at a specified speed.

The current adjusts itself to the load, see

.

The DC braking current set in

C00036

is

injected.

After the hold time (

C00106

) has expired,

a pulse inhibit is set.

Speed setpoint

Actual speed value of the motor

Controller output current

Disable voltage

DC-injection braking is active

0

1

2

3

4

C00106

C00036

C00019

Œ



Ž

The motor rotates at a specified speed.

The current adjusts itself to the load, see

.

The current sets itself load-dependent

until the hold time (

C00106

) has expired.

The actual speed value of the motor

follows the speed setpoint. The resulting

current depends on the load.

Speed setpoint

Actual speed value of the motor

Controller output current

Disable voltage

DC-injection braking is active

0

1

2

3

4

C00106

C00019

Œ



Ž