C02581 | holding brake: speed thresholds, C02582 | holding brake: setting, C02582 – Lenze 8400 StateLine User Manual

Page 818: C02581/1, C02581/2, C02581/3, C02581/4, C02581/5, C02582/bit 4, Selection of

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02581

818

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02581

C02582

Parameter | Name:

C02581 | Holding brake: Speed thresholds

Data type: INTEGER_16

Index: 21994

d

= 55EA

h

Speed setpoint threshold and hysteresis for automatic holding brake control

Holding brake control

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C02581/1

5.00 %

Holding brake: Switching threshold

• Switching threshold of the speed setpoint from which

on the holding brake is released/applied

automatically.

C02581/2

1.00 %

Holding brake: Hyst.release

• Hysteresis for holding brake release.

• Release threshold = switching threshold + release

hysteresis

C02581/3

1.00 %

Holding brake: Hyst. close

• Hysteresis for holding brake application.

• Application threshold = switching threshold -

application hysteresis

C02581/4

0.00 %

Holding brake: FF control starting value 1

From version 11.00.00

C02581/5

0.00 %

Holding brake: FF control starting value 2

From version 11.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Activation of functional holding brake control options

Holding brake control

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x40 (decimal: 64)

Value is bit-coded: (= bit set)

Info

Bit 0  bMBrakeReleaseOut invert.

Activation of inverted control

• 1 ≡ Inverted logic of the control signal for the holding

brake control switching element.

Bit 1  Horizontal brake protection

Brake response in case of pulse inhibit

• 1 ≡ In the case of a pulse inhibit, the actual speed

value is monitored which must reach the "Close"

threshold value to cause the holding brake to be

applied.

Note:

• This function is only active if bit 3

(horizontal/winding technology) is set as well. The

function is used in order that, when the controller is

inhibited, the holding brake of a drive with horizontal

traverse path does not wear out during rotation.

• With vertical motion (bit 3 = 0), this function is not

active. Especially with hoists and activated pulse

inhibit of the controller, an immediate application of

the brake is essential for safety-related reasons!

Advertising