System bus "CAN on board"

11.8

Process data transfer

520

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

The communication parameters such as the transmission mode and cycle time can be set freely for

every PDO and independently of the settings of other PDOs:

Blocking time
In

C00324/x

a "blocking time" can be set which defines the shortest transmission cycle with the

transmission type"asynchronous - manufacturer-specific/device profile-specific".
Example: Cycle time = 500 ms, blocking time = 100 ms, sporadic data change:

• With a sporadic data change < 500 ms, quickest transmission takes place every 100 ms due to

the set blocking time (event-controlled transmission). The transmission cycle timer is reset to 0

if the transmission has been activated in an event-controlled way.

• In the case of a sporadic data change > 500 ms, due to the cycle time set, transmission takes

place every 500 ms (cyclic transmission).

Tip!
The communication parameters can also be set via the following CANopen objects:

I-1400

...

I-1403

: Communication parameters for RPDO1 ... RPDO4

I-1800

...

I-1803

: Communication parameters for TPDO1 ... TPDO4

Parameter

Info

Lenze setting

Value Unit

CAN1_OUT

C00322/1

Transmission mode

254

C00324/2

Blocking time

0 ms

C00356/5

Cycle time

0 ms

C00358/1

Data length

8 Bytes

CAN2_OUT

C00322/2

Transmission mode

254

C00324/3

Blocking time

0 ms

C00356/2

Cycle time

0 ms

C00358/2

Data length

8 Bytes

CAN3_OUT

C00322/3

Transmission mode

254

C00324/4

Blocking time

0 ms

C00356/3

Cycle time

0 ms

C00358/3

Data length

8 Bytes

CAN4_OUT

(from version 15.00.00

C00322/4

Transmission mode

254

C00324/5

Blocking time

0 ms

C00356/6

Cycle time

0 ms

C00358/4

Data length

8 Bytes

CAN1_IN ... CAN4_IN

C00323/1...4

Transmission mode CAN1_IN ... CAN4_IN

• In the case of the RPDO serves as

monitoring setting in the case of sync-

controlled PDOs.

254

Advertising