C01092/1...3

Error status

• If bFail = TRUE:

Error status is displayed.

• Subcode 1 = LS_ParReadWrite_1

Subcode 2 = LS_ParReadWrite_2

Subcode 3 = LS_ParReadWrite_3

0 No error

33803 Invalid data type (e.g. STRING)
33804 Limit violation
33806 Invalid code
33813 No element of the selection list
33815 Writing of the parameter not

permitted

33816 Writing of the parameter only

permitted if controller is inhibited

33829 Invalid subcode
33865 No parameter with subcodes

C01093/1...3

(from version 06.00.00)

Arithmetic mode

• Lenze setting:"0: No arithmetic"

Arithmetic function

0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647

C01094/1...3

(from version 06.00.00)

-32767

32767 Counter

• For internal conversion in

arithmetic modes 1 ... 3.

• Lenze setting: 1

C01095/1...3

(from version 06.00.00)

1

32767 Denominator

• For internal conversion in

arithmetic modes 1 ... 3.

• Lenze setting: 1