2.4.3

Device personalisation

The controller and the memory module are married via the device personalisation by means of a

binding ID. When the device personalisation is active, all write/read actions between controller and

memory module are only executed if both components have the same binding ID.

If, for instance, a parameter set has been loaded from the memory module with an active device

personalisation, saving of this parameter set on another memory module with a different or non-

existent binding ID is not possible.

• Thus, copying the parameter set from a personalised memory module to a non-personalised

memory module is not possible!

Two types of checks are distinguished:

• If a differing binding ID is detected when the controller is switched on (during device

initialisation):

• the "Fault" error response is returned.
• The "

PS10: Invalid memory module binding

" error message is entered into the logbook.

• If a differing binding ID is detected while a device command for loading/saving the parameter

set is executed:

• Loading/saving is not executed.
• A corresponding status for the device command is output in

C00003

.

Short overview of the relevant parameters for device personalisation:

Lenze delivery status:

Procedure carried out by the

customer:

Impermissible replacement by the

end user:

No binding ID is set.

Customer sets binding ID for device

personalisation.

When device personalisation is

active:

The replacement of the controller or

memory module causes an error

message if the binding ID is incorrect

or not available.

Parameter

Info

Lenze setting

C00505/2

Binding ID

• The binding ID must have a length of 4 ... 16 characters.

• The binding ID may consist of any character. However, this is not

sensible. Recommended characters are: lower case letters (a - z),

upper case letters (A - Z) and digits (0 - 9).

Note:

After the execution of one of the device commands listed below, this

parameter returns the current binding ID status:

off No binding ID is set.

on Binding ID is set.

Highlighted in grey = display parameter

---

---