1 general information, 1 general data and application conditions, General data and application conditions – Lenze 8400 StateLine User Manual

Page 489: 11 system bus "can on board

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

489

11

System bus "CAN on board"

11.1

General information

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.1

General information

For many years, the system bus (CAN) based on the CANopen communication profile has been

integrated in Lenze controllers. Due to the lower number of data objects available, the functionality

and compatibility of the previous system bus are lower as compared to CANopen. For parameter

setting, two parameter data channels are always available to the user while CANopen provides only

one active parameter channel.
The system bus (CANopen) of the Inverter Drives 8400 is a further development of the system bus

(CAN) including the following properties:

• Full compatibility with CANopen DS301 V4.02.
• Support of the "Heartbeat" NMT slave function (DS301 V4.02)
• 1 or 2 parameterisable parameter data channels for transmitting SDOs (Service Data Objects)
• Up to four parameterisable process data channels (dependent on the device version) for

transmitting PDOs (Process Data Objects)

• All process data channels are functionally equivalent
• Monitoring of the receive PDOs for data reception

• Adjustable error response to ...

• physical CAN errors (frame, bit, ACK error)
• bus-stop, bus working
• absent PDOs

• Telegram counters for SDOs and PDOs
• Bus status diagnostics
• Boot-up telegram generation
• Emergency telegram generation
• Reset node telegram generation (for master configuration)
• Sync telegram generation and response to sync telegrams:

• Data transmission/reception
• Device-internal time base synchronisation

• Abort codes
• All CAN on board functions can be parameterised via codes
• Object directory (all mandatory functions, optional functions, indexes)

11.1.1

General data and application conditions

Range

Values

Communication profile

CANopen, DS301 V4.02

Communication medium

DIN ISO 11898

Network topology

Line terminated at both ends

Adjustable node addresses

(max. number of nodes)

Depending on the number of SDO channels set in

C00366

:

• 1 SDO: Node address 1 ... 127 (max. 127 nodes)

• 2 SDO: Node address 1 ... 63 (max. 63 nodes)

• adjustable via DIP switches or via code

C00350

.

Adjustable baud rates

20, 50, 125, 250, 500, 1000 kbps

• adjustable via DIP switches or via code

C00351

.

• 1000 kbps are supported

from version 11.00.00

.

Advertising