Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

713

15

Parameter reference

15.2

Parameter list | C00606

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00606

C00607

C00608

C00609

C00610

Parameter | Name:

C00606 | Resp. to motor overload (I²xt)

Data type: UNSIGNED_8

Index: 23969

d

= 5DA1

h

Response when the motor load displayed in

C00066

reaches the value "100.00 %".

Motor overload monitoring (I2xt)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00607 | Resp. to max freq. feedb. DIG12/67

Data type: UNSIGNED_8

Index: 23968

d

= 5DA0

h

Response when the maximum input frequency has been reached via the digital inputs.
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00608 | Resp. to maximum torque

Data type: UNSIGNED_8

Index: 23967

d

= 5D9F

h

Response if the maximum torque (

C00057

) is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00609 | Resp. to maximum current

Data type: UNSIGNED_8

Index: 23966

d

= 5D9E

h

Response if the maximum current (

C00022

,

C00023

) is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00610 | 16-bit connection table

Data type: UNSIGNED_16

Index: 23965

d

= 5D9D

h

This code is for device-internal use only and must not be written to by the user!