C02864 | mctrl: optimisiations, C02864/1, 15 parameter reference – Lenze 8400 StateLine User Manual

Page 827

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

827

15

Parameter reference

15.2

Parameter list | C02864

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02864

Parameter | Name:

C02864 | MCTRL: Optimisiations

Data type: UNSIGNED_16

Index: 21711

d

= 54CF

h

From version 14.00.00

Activation of special functions of the internal motor control
Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Motor temp. 90° for operation

without KTY

1 ≡ Warm machine. In case the temperature tracking is

not active, a motor temperature of 90 °C is assumed.

Bit 1 No switch-off of the brake chopper

after 4s

1 ≡ Limitation of the operating time of the brake chopper

(brake transistor) is deactivated.

Braking operation/brake energy management

Bit 2 Brake chopper off in case of trip

0 ≡ No response of the brake chopper in the "Fault"

device status.

1 ≡ In the "Fault" device status, the brake chopper is

permanently switched off without any delay.

Braking operation/brake energy management

Bit 3 Reserved (do not change!)
Bit 4 Motor ident: Switching frequency

8kHz

Switching frequency for motor parameter identification:

0 ≡ 4 kHz

1 ≡ 8 kHz

Preventing a decrease of the switching frequency

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8 Suppress V/f emergency operation

From version 15.00.00

, it is internally switched to the

encoderless V/f characteristic control in case of a motor

control type with feedback and an encoder open circuit

in order to avoid impermissible motor movements.

• In order that this "V/f emergency operation" works

properly, the parameters relevant for the V/f

characteristic control (base frequency, Vmin boost,

slip compensation, etc.) have to be set correctly. As an

alternative, a motor parameter identification can be

executed as well.

• The change-over to "V/f emergency operation" is

reported via bit 4 in

C01000

and via the

bWirebreakUfLinearActive status signal at the

SB

LS_DeviceMonitor

.

• The setting in

C00006

is not affected by the change-

over.

The "V/f emergency operation" can be suppressed by

setting bit 8 to "1".

0 ≡ V/f emergency operation in case of encoder open

circuit

1 ≡ No V/f emergency operation in case of encoder open

circuit

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved