5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 110

Advertising
background image

5

Motor control (MCTRL)

5.1

Motor selection/Motor data

110

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Accepting the default values of the motor
If a motor is selected from the motor catalogue at a later time, the Use motor's default values dialog

box is displayed afterwards which includes all motor data of the selected motor. Please select here

which of the default values are to be copied to the controller:

• The listed motor parameters are already optimally preset for the selected Lenze motor. An

adaptation is not required.

• The "plant parameter" term comprises all parameters that result from the combination of

motor and load. These characterise the transfer behaviour of the entire controlled system.

• The plant parameters depend on the application in which the controller and motor are used.
• When a Lenze motor is selected in the »Engineer«, plant parameters are suggested for this

motor for a load-free operation.

Tip!
If a third party manufacturer's motor is used, select a Lenze motor from the motor

catalogue first which is similar in terms of current, voltage and speed rating. Adapt the

preselected motor data exactly to the real motor afterwards.