5

Motor control (MCTRL)

5.9

Parameterisable additional functions

202

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.9

Parameterisable additional functions

5.9.1

Selection of switching frequency

The switching frequency of the inverter that can be selected in

C00018

influences the smooth

running performance and the noise generation in the connected motor as well as the power losses

in the controller.
The lower the switching frequency the higher the concentricity factor, the smaller the losses, and

the higher the noise generation.

Short overview of the relevant parameters:

Stop!

If operated at a switching frequency of 16 kHz, the output current of the controller must

not exceed the current limit values specified in the technical data! (See chapter "Rated

data" of the hardware manual.)

Note!

• Operate mid-frequency motors only at a switching frequency of 8 kHz or 16 kHz

(var./drive-opt.).

• If operated at a switching frequency of 16 kHz, the Ixt evaluation (

C00064

) is

considered including the required derating to 67 % of the rated device current at

switching frequencies of 2.4 and 8 kHz.

• Ensure that the value does not fall below the permissible switching frequency,

• if the motor is not approved for the setting switching frequency

- or -

• if a sinusoidal filter has been connected between the output of the inverter and the

motor which is not approved for the setting switching frequency.

(see section "

Preventing a decrease of the switching frequency

")

Parameter

Info

Lenze setting

Value Unit

C00018

Switching frequency

2: "8 kHz var./drive-opt."

C00144

Switching frequency reduction (temp.)

1: On

C00725

Current switching frequency

-

C00910/1

Max. pos. output frequency

1000 Hz

C00910/2

Max. neg. output frequency

1000 Hz

C02864/1

Bit 4:

MCTRL: Special settings 2

Option "Motor ident: Switching frequency 8 kHz"

(from version 14.00.00)

0x0000

(Off)

Highlighted in grey = display parameter