Parameter list | C00806

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00806

C00820

C00821

Parameter | Name:

C00806 | L_MPot_1: Use

Data type: UNSIGNED_8

Index: 23769

d

= 5CD9

h

The

L_MPot_1

FB: Use of the motor potentiometer

Selection list

(Lenze setting printed in bold)

Info

0 No

The motor potentiometer is not used.

• The analog value applied to the nIn_a input is looped

through without any changes to the nOut_a output.

1 Yes

The motor potentiometer is used.

• The analog value applied at the nIn_a input is led via

the motor potentiometer and provided at the nOut_a

output.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00820 | L_DigitalLogic_1: Function

Data type: UNSIGNED_8

Index: 23755

d

= 5CCB

h

The

L_DigitalLogic_1

FB: Selection of the internal logic function

Selection list

(Lenze setting printed in bold)

Info

0 bOut = 0

Constant value "FALSE"

1 bOut = 1

Constant value "TRUE"

2 bOut = bIn1 AND bIn2 AND bIn3

AND operation

3 bOut = bIn1 OR bIn2 OR bIn3

OR operation

4 bOut = f (truth table)

The truth table parameterised in

C00821

is used.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00821 | L_DigitalLogic_1: Truth table

Data type: UNSIGNED_8

Index: 23754

d

= 5CCA

h

The

L_DigitalLogic_1

FB: Parameterisation of the truth table

Selection list

0 False
1 True

Subcodes

Lenze setting

Info

C00821/1

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=0 0 0

C00821/2

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=0 0 1

C00821/3

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=0 1 0

C00821/4

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=0 1 1

C00821/5

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=1 0 0

C00821/6

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=1 0 1

C00821/7

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=1 1 0

C00821/8

0: FALSE

L_DigitalLogic_1

: bIn3...bIn1=1 1 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1