1 function 0: evaluate rising signal edges, 2 function 1: evaluate falling signal edges, Function 0: evaluate rising signal edges – Lenze 8400 StateLine User Manual

Page 985: Function 1: evaluate falling signal edges, 17 function library

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

985

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.44.1 Function 0: Evaluate rising signal edges

[17-24] Switching performance for function selection "0: High edge"

Functional sequence

1. A FALSE-TRUE edge at the bIn input sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless

another FALSE/TRUE edge has been set at the bIn input.

• If an additional FALSE-TRUE edge occurs at the bIn input, the pulse duration starts again from

the beginning, i.e. the bOut output can be retriggered.

17.1.44.2 Function 1: Evaluate falling signal edges

[17-25] Switching performance for function selection "1: Low edge"

Functional sequence

1. A TRUE-FALSE edge at the bIn inputs sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless

another TRUE/FALSE edge has been set at the bIn input.

• If an additional TRUE-FALSE edge occurs at the bIn input, the pulse duration starts again from

the beginning, i.e. the bOut output can be retriggered.

Pulse duration

TRUE

FALSE

bOut

t

TRUE

FALSE

bIn

t

Œ

Œ

Œ

Pulse duration

TRUE

FALSE

bOut

t

TRUE

FALSE

bIn

t

Œ

Œ

Œ

Advertising