C00692 | l_compare_3: window, C00696 | l_offsetgainp_1: offset, C00697 | l_offsetgainp_2: offset – Lenze 8400 StateLine User Manual

Page 729: C00698 | l_offsetgainp_3: offset, C00699 | l_muldiv_1: parameter, C00696, C00697, Can be set in, C00698, T in

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

729

15

Parameter reference

15.2

Parameter list | C00692

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00692

C00696

C00697

C00698

C00699

Parameter | Name:

C00692 | L_Compare_3: Window

Data type: INTEGER_16

Index: 23883

d

= 5D4B

h

From version 11.00.00

FB

L_Compare_3

: window for the comparison operation selected in

C00690

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00696 | L_OffsetGainP_1: Offset

Data type: INTEGER_16

Index: 23879

d

= 5D47

h

The

L_OffsetGainP_1

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00697 | L_OffsetGainP_2: Offset

Data type: INTEGER_16

Index: 23878

d

= 5D46

h

The

L_OffsetGainP_2

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00698 | L_OffsetGainP_3: Offset

Data type: INTEGER_16

Index: 23877

d

= 5D45

h

The

L_OffsetGainP_3

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00699 | L_MulDiv_1: Parameter

Data type: INTEGER_16

Index: 23876

d

= 5D44

h

The

L_MulDiv_1

FB: Numerator and denominator

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C00699/1

0

L_MulDiv_1

: Numerator

C00699/2

10000

L_MulDiv_1

: Denominator

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising