15.2

Parameter list | C02314

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02314

C02315

C02580

Parameter | Name:

C02314 | Reserved

Data type: UNSIGNED_8

Index: 22261

d

= 56F5

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02315 | LS_WriteParamList: Manual entry of motor type

Data type: UNSIGNED_8

Index: 22260

d

= 56F4

h

From version 14.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Selection list

0 Automatic
1 ASM
2 PSM

Subcodes

Lenze setting

Info

C02315/1

0: Automatic

LS_WriteParamList

: c1001_s1_val1

C02315/2

0: Automatic

LS_WriteParamList

: c1001_s1_val2

C02315/3

0: Automatic

LS_WriteParamList

: c1001_s1_val3

C02315/4

0: Automatic

LS_WriteParamList

: c1001_s1_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02580 | Holding brake: Operating mode

Data type: UNSIGNED_8

Index: 21995

d

= 55EB

h

Selection of the operating mode for holding brake control

Holding brake control

Selection list

(Lenze setting printed in bold)

Info

0 Brake control off

No holding brake is used. Internal control is switched off.

11 Manually controlled

The holding brake is released and closed via a control bit

in the MCK control word.

12 Autom. controlled

The holding brake is automatically released and closed

via speed setpoint comparisons.

13 Semi-automat. controlled

From version 11.00.00

The holding brake is released and closed via a control bit

in the MCK control word.

• In contrast to the manual operation (mode 11)

• the feedforward control is active in this mode,

preventing a sagging e.g. in case of a hoist.

• the brake in this mode also closes when the

controller is inhibited in order to prevent the axis in

a hoist from falling.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT