5

Motor control (MCTRL)

5.8

Sensorless control for synchronous motors (SLPSM)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.8.1

Parameterisation dialog/signal flow

Proceed as follows to open the dialog for parameterising the motor control:

1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Select the motor control "3: SLPSM: Sensorless PSM" from the Overview dialog level in the

Motor control list field:

4. Click the Motor control servo SLPSM button to change to the OverviewMotor control

vector dialog box.

• This dialog level only shows a simplified signal flow with the most important

parameters.

• When you click the >>More details button in the left-most position, a signal flow with

more details/parameters is displayed.