C02301 | ls_writeparamlist: slpsm: switching speed, C02301/1, C02301/2 – Lenze 8400 StateLine User Manual

Page 812: C02301/3, C02301/4, C02301/5, C02301/6, C02301/7, C02301/8, C02302/1

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02301

812

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02301

C02302

C02303

Parameter | Name:

C02301 | LS_WriteParamList: SLPSM: Switching speed

Data type: INTEGER_16

Index: 22274

d

= 5702

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02301/1

13.00 %

LS_WriteParamList

: c996_s1_val1

C02301/2

13.00 %

LS_WriteParamList

: c996_s1_val2

C02301/3

13.00 %

LS_WriteParamList

: c996_s1_val3

C02301/4

13.00 %

LS_WriteParamList

: c996_s1_val4

C02301/5

8.00 %

LS_WriteParamList

: c996_s2_val1

C02301/6

8.00 %

LS_WriteParamList

: c996_s2_val2

C02301/7

8.00 %

LS_WriteParamList

: c996_s2_val3

C02301/8

8.00 %

LS_WriteParamList

: c996_s2_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02302 | LS_WriteParamList: SLPSM: Filter time - rotor position

Data type: INTEGER_16

Index: 22273

d

= 5701

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02302/1

5.00 %

LS_WriteParamList

: c997_val1

C02302/2

5.00 %

LS_WriteParamList

: c997_val2

C02302/3

5.00 %

LS_WriteParamList

: c997_val3

C02302/4

5.00 %

LS_WriteParamList

: c997_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02303 | LS_WriteParamList: SLPSM: Filter time rotor position

Data type: INTEGER_16

Index: 22272

d

= 5700

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.5

ms

20.0

Subcodes

Lenze setting

Info

C02303/1

3.0 ms

LS_WriteParamList

: c998_s1_val1

C02303/2

3.0 ms

LS_WriteParamList

: c998_s1_val2

C02303/3

3.0 ms

LS_WriteParamList

: c998_s1_val3

C02303/4

3.0 ms

LS_WriteParamList

: c998_s1_val4

C02303/5

5.0 ms

LS_WriteParamList

: c998_s2_val1

C02303/6

5.0 ms

LS_WriteParamList

: c998_s2_val2

C02303/7

5.0 ms

LS_WriteParamList

: c998_s2_val3

C02303/8

5.0 ms

LS_WriteParamList

: c998_s2_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Advertising