Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

291

6

I/O terminals

6.4

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.4.2

Changing the terminal assignment with the keypad

You can reconfigure the preconfigured terminal assignment with the keypad (and with the

»Engineer«) by means of so-called configuration parameters.

• Each configuration parameter represents a signal input of a system block or application block.
• Each configuration parameter contains a selection list with output signals of the same type of

data.

• Logical linking is thus carried out by selecting the output signal for the corresponding signal

input.

In the following example, digital output 1 (LS_DigitalOutput.bOut1 input) is logically linked to the

status signal "Drive ready" (LA_nCtrl_bDriveReady output signal):

Configuration parameters for the analog and digital output terminals
The preconfigured assignment of the analog and digital output terminals can be altered by means

of the subcodes of

C00620

and

C00621

:

Other subcodes (not shown here) allow the configuration of input signals of different system blocks

and port blocks.

Parameter

Info

Lenze setting

Value Unit

Analog outputs - terminal assignment

C00620/1

LS_AnalogOutput: nOut1_a

1003: LA_nCtrl_nMotorSpeedAct_a

Digital outputs - terminal assignment

C00621/1

LS_DigitalOutput:bRelay

1001: LA_nCtrl_bDriveFail

C00621/2

LS_DigitalOutput:bOut1

1000: LA_nCtrl_bDriveReady

Advertising