Working with the FB Editor

16.2

User interface

868

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

"Application interconnection" level
This level displays the interconnection of the application selected in

C00005

in detail. All function

blocks used in the application and the system blocks which provide the interfaces to the drive and

motor interface and to the MotionControlKernel (MCK) are displayed with their connections.

• The interconnection of the I/Os of the controller with the inputs and outputs of the application

is masked out in this level.

[16-6] Schematic diagram of "Application interconnection"

Tip!
Every application block features so-called "free inputs and outputs" which you can use to

transfer signals from the I/O level to the application level and vice versa.

• In the Lenze setting, these connectors are hidden in the function block editor.
• These connections can be shown via the Connector visibilities command in the Context

menu of the application block.

"Free interconnection" level
This level serves to implement an individual drive solution for the device versions "StateLine C"

(from version 12.00.00 and »Engineer« V2.17)

, "HighLine C" and "TopLine C".

Note!

When you select the "Free interconnection" level for the first time, you are prompted to

confirm whether the interconnection from the I/O level and the application level are to

be combined and copied into this level.
When you confirm this confirmation prompt with Yes, the I/O level and the application

level are not available anymore. This action can only be undone by resetting the

application to a predefined Lenze application!

Resetting changed interconnection

( 901)