15

Parameter reference

15.2

Parameter list | C00007

602

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00007

11 VFCplusEco: V/f energy-saving

From version 10.00.00

This control type is used for energy-saving speed control

of an asynchronous motor via a linear V/f characteristic.

• For setting the V/f characteristic, only the rated

frequency (

C00089

) and the rated voltage (

C00090

) of

the motor have to be entered.

• Predestinated application areas of this control type

are materials handling technology and pump and fan

systems.

V/f characteristic control, energy-saving

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00006 | Motor control

Data type: UNSIGNED_8

Index: 24569

d

= 5FF9

h

Parameter | Name:

C00007 | Control mode

Data type: UNSIGNED_16

Index: 24568

d

= 5FF8

h

With this parameter the control mode for the technology application selected under

C00005

is defined, i.e. how the

inputs and outputs of the technology application are connected to the I/Os of the controller.

• How the inputs and outputs are connected in the individual control modes is described in the corresponding

technology application:

"Actuating drive speed" TA

TA "actuating drive speed (AC Drive Profile)"

"Switch-off positioning" TA

Selection list

(Lenze setting printed in bold)

Info

0 Wiring has changed

This is displayed when the FB interconnection has been

changed in the I/O level via the FB Editor.

10 Terminals 0

The technology application is controlled via the digital

and analog input terminals of the controller.

• For a short overview of the preconfigured terminal

assignment see the following section "

Terminal

assignment of the control modes 10 ... 16

".

12 Terminals 2
14 Terminals 11
16 Terminal 16
20 Keypad

The technology application is controlled via the keypad.

21 PC

The technology application is controlled via the "Free

parameters" of the controller (PC control).

30 CAN

The technology application is controlled by means of

CAN-PDOs via the system bus "CAN on board".

"CAN on board" system bus

40 MCI

The technology application is controlled by means of

MCI-PDOs via the MCI-interface of an attached

communication module (e.g. PROFIBUS).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1