Technology applications

7.2

TA "Actuating drive speed"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

nTorqueMotLim_a

nTorqueGenLim_a

INT

Torque limitation in motor mode and in generator mode

• These input signals are directly transferred to the motor control to limit the

controller's maximum torque in motor and generator mode.

• The drive cannot output a higher torque in motor/generator mode than set here.

• The applied values (any polarity) are internally interpreted as absolute values.

• If V/f characteristic control (VFCplus) is selected, limitation is indirectly

performed via a so-called I

max

controller.

• If sensorless vector control (SLVC) is selected, limitation has a direct effect on the

torque-producing current component.

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

Torque limits in motor and generator mode:

bSetSpeedCcw

BOOL

Change of direction of rotation

• For instance if a motor or gearbox is fixed laterally reversed to a machine part, but

the setpoint selection should still be executed for the positive direction of

rotation.

FALSE Clockwise rotation (Cw)

TRUE Direction of rotation to the left (Ccw)

bRLQCw

BOOL

Activate clockwise rotation (fail-safe)

• For a detailed functional description see the

L_RLQ

FB.

FALSE Quick stop

TRUE CW rotation

bRLQCcw

BOOL

Activate counter-clockwise rotation (fail-safe)

• For a detailed functional description see the

L_RLQ

FB.

FALSE Quick stop

TRUE Counter-clockwise rotation

nMainSetValue_a

INT

Main speed setpoint

• Offset and gain of this input signal can be set in

C00696

and

C00670

for a simple

signal adjustment of a setpoint encoder.

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

• The main setpoint is transformed to a speed setpoint in the setpoint encoder via

a ramp function generator with linear or S-shaped ramps.

• Upstream to the ramp function generator, a blocking speed masking function

and a setpoint MinMax limitation are effective.

• For a detailed functional description see the

L_NSet

FB.

Identifier

Data type

Information/possible settings

n

N

M

N

M

-M

N

-n

N

n

TorqueMotLim

TorqueGenLim

TorqueMotLim

TorqueMotLim

TorqueGenLim