C00994 | flying restart fct.: current, C00995 | slpsm: controlled current setpoint, C00996 | slpsm: switching speed – Lenze 8400 StateLine User Manual

Page 773: C00997 | slpsm: filter cutoff frequency, C00995/1, C00995/2, C00996/1, C00996/2, In [%] with, Current in

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

773

15

Parameter reference

15.2

Parameter list | C00994

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00994

C00995

C00996

C00997

Parameter | Name:

C00994 | Flying restart fct.: Current

Data type: INTEGER_16

Index: 23581

d

= 5C1D

h

Current to be injected during the flying restart process

• 100 % ≡ rated motor current (

C00088

).

• The flying restart current should amount to 10 ... 25 % of the rated motor current.

Flying restart fct.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 25.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00995 | SLPSM: Controlled current setpoint

Data type: UNSIGNED_16

Index: 23580

d

= 5C1C

h

From version 10.00.00

Sensorless control for synchronous motors (SLPSM)

Setting range

(min. value | unit | max. value)

5.00

%

400.00

Subcodes

Lenze setting

Info

C00995/1

100.00 %

SLPSM

: Controlled accelerating current

C00995/2

20.00 %

SLPSM

: Controlled standstill current

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00996 | SLPSM: Switching speed

Data type: INTEGER_16

Index: 23579

d

= 5C1B

h

From version 10.00.00

Sensorless control for synchronous motors (SLPSM)

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00996/1

13.00 %

SLPSM

: Switching speed, closed-loop control

C00996/2

8.00 %

SLPSM

: Switching speed, open-loop control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00997 | SLPSM: Filter cutoff frequency

Data type: INTEGER_16

Index: 23578

d

= 5C1A

h

From version 10.00.00

Sensorless control for synchronous motors (SLPSM)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 5.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising