6 table of attributes, 15 parameter reference, 6 table of attributes 844 – Lenze 8400 StateLine User Manual

Page 844

Advertising
background image

15

Parameter reference

15.6

Table of attributes

844

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

15.6

Table of attributes

The table of attributes contains information required for a communication with the controller via

parameters.

How to read the table of attributes:

Column

Meaning

Entry

Code

Parameter name

Cxxxxx

Name

Parameter short text (display text)

Text

Type

Parameter type

Selection list

Value from selection list

Bit coded

Bit-coded value

Linear value

Value with setting range

String

String of digits

Index

dec

Index under which the parameter is addressed.

The subindex for array variables corresponds to the

Lenze subcode number.

24575 - Lenze code number

Is only required for access via a bus

system.

hex

5FFF

h

- Lenze code number

Data

DS

Data structure

E

Single variable

(only one parameter element)

A

Array variable

(several parameter elements)

DA

Number of array elements (subcodes)

Number

DT

Data type

INTEGER_16

2 bytes with sign

INTEGER_32

4 bytes with sign

UNSIGNED_8

1 byte without sign

UNSIGNED_16

2 bytes without sign

UNSIGNED_32

4 bytes without sign

VISIBLE_STRING [xx]

ASCII string (with character length xx)

Factor

Factor for data transmission via a bus system,

depending on the number of decimal positions

Factor

1 ≡ no decimal positions

10 ≡ 1 decimal position

100 ≡ 2 decimal positions

1000 ≡ 3 decimal positions

10000 ≡ 4 decimal positions

CINH

Writing is only possible if the controller is inhibited CINH

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

C00001

Keypad UserLevel

Selection list

24574

5FFE

A

1

UNSIGNED_8

1

C00002

Device commands

Selection list

24573

5FFD

A

33

UNSIGNED_8

1

C00003

Status of the last device command

Selection list

24572

5FFC

E

1

UNSIGNED_8

1

C00005

Application

Selection list

24570

5FFA

E

1

UNSIGNED_16

1

C00006

Motor control

Selection list

24569

5FF9

E

1

UNSIGNED_8

1

C00007

Control mode

Selection list

24568

5FF8

E

1

UNSIGNED_16

1

C00008

Original application|control source

Selection list

24567

5FF7

E

1

UNSIGNED_16

1

C00010

AIN1: Characteristic

Linear value

24565

5FF5

A

8

INTEGER_16

100

C00011

Appl.: Reference speed

Linear value

24564

5FF4

E

1

UNSIGNED_16

1

C00012

Accel. time - main setpoint

Linear value

24563

5FF3

E

1

UNSIGNED_32

1000

C00013

Decel. time - main setpoint

Linear value

24562

5FF2

E

1

UNSIGNED_32

1000

C00015

VFC: V/f base frequency

Linear value

24560

5FF0

E

1

UNSIGNED_16

10

C00016

VFC: Vmin boost

Linear value

24559

5FEF

E

1

UNSIGNED_16

100

C00018

Switching frequency

Selection list

24557

5FED

E

1

UNSIGNED_8

1

C00019

Auto-DCB: Threshold

Linear value

24556

5FEC

E

1

UNSIGNED_16

1

C00021

Slip comp.

Linear value

24554

5FEA

E

1

INTEGER_16

100

C00022

Imax in motor mode

Linear value

24553

5FE9

E

1

UNSIGNED_16

100

C00023

Imax in generator mode

Linear value

24552

5FE8

E

1

INTEGER_16

100

Grayed out = display parameter (read access only)