Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

953

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Inputs

Outputs

Identifier

Data type

Information/possible settings

nCInhVal_a

INT

Main setpoint signal which is to be accepted by the main setpoint integrator when

the controller is inhibited.

bRfgStop

BOOL

Holding (freezing) of the current value of the main setpoint integrator

TRUE The current value of the main setpoint integrator is held.

bRfg0

BOOL

Leading the main setpoint integrator to 0 within the current Ti times

TRUE The current value of the main setpoint integrator is led to "0" within

the Ti time set.

bNSetInv

BOOL

Signal inversion for the main setpoint

TRUE Main setpoint signal is inverted.

nNset_a

INT

Main setpoint signal

• Other signals are also permitted

bJog1 ... bJog8

BOOL

Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint

• Selection inputs are binary coded.

bTI1 ... bTI8

BOOL

Selection inputs for alternative acceleration/deceleration times for the main

setpoint

• Selection inputs are binary coded.

nSet_a

INT

Starting value which is loaded into the main setpoint integrator by setting bLoad to

TRUE.

bLoad

BOOL

Control of both ramp function generators in special situations, e.g. QSP

TRUE The nSet_a input signal is loaded into the main setpoint integrator

and the additional setpoint integrator is set to "0".

bAddInv

BOOL

Signal inversion for the additional setpoint

TRUE Additional setpoint signal is inverted.

nNAdd_a

INT

Additional setpoint signal

• Other signals are also permitted

bExternalCINH

BOOL

Additional load input for the main setpoint integrator and the additional setpoint

integrator

TRUE The main setpoint integrator is set to the value applied at

nCInhVal_a.

The additional setpoint integrator is set to "0".

Application example for the additional load function

( 962)

Identifier

Data type

Value/meaning

nNOut_a

INT

Speed setpoint output signal

• Scaling: 16384 ≡ 100 %

bRfgIEqO

BOOL

Status signal "setpoint = 0"