Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

293

6

I/O terminals

6.4

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.4.3

Changing the terminal assignment with the »Engineer«

Whereas the configuration parameters referred to have to be parameterised with the keypad,

implementation in the »Engineer« is much easier due to the availability of the corresponding

dialogs. The following task illustrates the respective procedure.
Task: Starting from the preset technology application "Actuating drive speed" and the "Terminals 0"

control mode, the DI2 digital input is to be used for choosing an alternative

acceleration/deceleration time for the main setpoint instead of for choosing the fixed setpoint 2/3.

To do this, the DI2 digital input is not to be linked to the bJogSpeed2 input but to the bJogRamp1

input of the application module.

Possibility 1: Change terminal assignment by means of the Terminal Assignment tab
Procedure:

1. Go to the Terminal Assignment tab and select "Digital terminals" in the Control connections list

field:

2. Click on the

button for the DI2 terminal in order to open the dialog box Assignment

Terminal --> Function block.

• In the list field, all block inputs that are currently logically linked to digital input DI2 are

marked with a checkmark:

3. Remove checkmark for the connection LA_NCtrl: bJogSpeed2 in order to cancel the existing

logical link.

4. Set checkmark for connection LA_NCtrl: bJogRamp1 in order to logically link this application

input to digital input DI2.