4 parameters with subcodes, 4 parameter attributes, Parameters with subcodes – Lenze 8400 StateLine User Manual

Page 595: Parameter attributes, 15 parameter reference

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

595

15

Parameter reference

15.1

Structure of the parameter descriptions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

15.1.3.4

Parameters with subcodes

Description structure

Parameter setting in the »Engineer«
The »Engineer« parameter list displays each subcode individually. The parameters are set as

described in the previous chapters.

15.1.4

Parameter attributes

The table footers contain the parameter attributes:

Parameter | Name:

Cxxxxx | _____________

Data type: _______

Index: _______

Description
Setting range

(min. value | unit | max. value)

Subcodes

Lenze setting

Cxxxxx/1
Cxxxxx/2
Cxxxxx/3
Cxxxxx/4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Attribute

Meaning

Read access

Read access to parameter possible.

Write access

Write access to parameter possible.

• Please also observe the following attributes:

CINH

Parameter value can only be changed when the controller is

inhibited.

PLC STOP

Parameter value can only be changed when the application is

stopped.

No transfer

Parameter is not transferred to controller when the command Download parameter set is

executed.

COM

Communication-relevant parameter

• This parameter is relevant for parameter data transfer via the (CAN) system bus.

MOT

Motor control parameters