C00385 | can node addr. heartbeat producer, C00386 | consumertime heartbeat producer, C00387 | can-gatewayaddr – Lenze 8400 StateLine User Manual

Page 675: C00386/1...n, C00385/1...n, Cer in, C00385/1, C00386/1, C00385/x, C00386/x

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

675

15

Parameter reference

15.2

Parameter list | C00385

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00385

C00386

C00387

Parameter | Name:

C00385 | CAN node addr. HeartBeat producer

Data type: UNSIGNED_8

Index: 24190

d

= 5E7E

h

From version 03.00.00

The subcodes represent the nodes to be monitored by heartbeat.

Heartbeat protocol

Setting range

(min. value | unit | max. value)

0

127

Subcodes

Lenze setting

Info

C00385/1

0

CAN node address HeartBeat Producer 1 ... 7

C00385/...
C00385/7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00386 | ConsumerTime HeartBeat Producer

Data type: UNSIGNED_16

Index: 24189

d

= 5E7D

h

From version 03.00.00

The subcodes represent the nodes to be monitored by heartbeat.

Heartbeat protocol

Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C00386/1

0 ms

ConsumerTime HeartBeat Producer 1 ... 7

C00386/...
C00386/7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00387 | CAN-GatewayAddr

Data type: UNSIGNED_8

Index: 24188

d

= 5E7C

h

From version 12.00.00

CAN gateway

Setting range

(min. value | unit | max. value)

0

127

Subcodes

Lenze setting

Info

C00387/1

0

CAN_Gateway: Addr.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1