663

15

Parameter reference

15.2

Parameter list | C00342

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00342

Parameter | Name:

C00342 | CAN decoupling PDOInOut

Data type: UNSIGNED_16

Index: 24233

d

= 5EA9

h

From version 04.00.00

Configuration defining the events that lead to a decoupling of the process data words.

Configuring exception handling of the CAN PDOs

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 BusOff_MsgErr
Bit 1 Warning
Bit 2 NodeStopped
Bit 3 HeartBeatEvent
Bit 4 CAN1_In_Überw.
Bit 5 CAN2_In_Überw.
Bit 6 CAN3_In_Überw.
Bit 7 CAN4_In_Überw.

From version 15.00.00

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14 Trouble
Bit 15 Fault

Subcodes

Lenze setting

Info

C00342/1

0x0000

CAN decoupling PDO_In from the bus

C00342/2

0x0000

CAN decoupling PDO_Out from the appl.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT