C00487 - application units, C00488 | l_jogctrledgedetect, C00488/x – Lenze 8400 StateLine User Manual

Page 695: C00488/1, C00488/2, C00488/3, C00488/4, C00488/5, C00488/6, 15 parameter reference

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

695

15

Parameter reference

15.2

Parameter list | C00487

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00487

C00488

Parameter | Name:

C00487 - Application units

Data type: INTEGER_32

Index: 24088

d

= 5E18

h

From version 06.00.00

SB

LS_DisFree_a

: Display of the input values in a configurable application unit

Display of internal process factors in application units

Display range

(min. value | unit | max. value)

-21474836.47

units

21474836.47

Subcodes

Info

C00487/1

Application units 1

C00487/2

Application units 2

C00487/3

Application units 3

C00487/4

Application units 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00488 | L_JogCtrlEdgeDetect

Data type: UNSIGNED_8

Index: 24087

d

= 5E17

h

From version 03.00.00

The

L_JogCtrlExtension_1

FB: Signal methodology

• Selection whether the corresponding function is to be activated by edge or level.

Selection list

0 Level
1 Edge

Subcodes

Lenze setting

Info

C00488/1

0: Level

InputSens.SlowDown1

• Selection of edge or level for starting slow-down

function 1

C00488/2

0: Level

InputSens.Stop1

• Selection of edge or level for stop function 1

C00488/3

0: Level

InputSens.SlowDown2

• Selection of edge or level for starting slow-down

function 2

C00488/4

0: Level

InputSens.Stop2

• Selection of edge or level for stop function 2

C00488/5

0: Level

InputSens.SlowDown3

• Selection of edge or level for starting slow-down

function 3

C00488/6

0: Level

InputSens.Stop3

• Selection of edge or level for stop function 3

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising