C00010 | ain1: characteristic, C00010, C00010/1 – Lenze 8400 StateLine User Manual

Page 605: C00010/2, C00010/3, C00010/4, C00010/5, C00010/6, C00010/7, C00010/8

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

605

15

Parameter reference

15.2

Parameter list | C00010

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00010

1116 SpeedACdrive|Klemme16

Application: Actuating drive speed (AC Drive Profile)

I/O level: "Terminal 16" control mode

1120 SpeedACdrive|Keypad

Application: Actuating drive speed (AC Drive Profile)

I/O level: "Keypad" control mode

1121 SpeedACdrive|PC

Application: Actuating drive speed (AC Drive Profile)

I/O level: "PC" control mode

1130 SpeedACdrive|CAN

Application: Actuating drive speed (AC Drive Profile)

I/O level: "CAN" control mode

1140 SpeedACdrive|MCI

Application: Actuating drive speed (AC Drive Profile)

I/O level: "MCI" control mode

3000 SwitchPos|Free

Application: Switch-off positioning

I/O level: Interconnection has been changed.

3010 SwitchPos|Terminal0

Application: Switch-off positioning

I/O level: "Terminals 0" control mode

3012 SwitchPos|Terminal 2

Application: Switch-off positioning

I/O level: "Terminal 2" control mode

3014 SwitchPos|Terminal 11

Application: Switch-off positioning

I/O level: "Terminal 11" control mode

3016 SwitchPos|Terminal 16

Application: Switch-off positioning

I/O level: "Terminal 16" control mode

3020 SwitchPos|Keypad

Application: Switch-off positioning

I/O level: "Keypad" control mode

3021 SwitchPos|PC

Application: Switch-off positioning

I/O level: "PC" control mode

3030 SwitchPos|CAN

Application: Switch-off positioning

I/O level: "CAN" control mode

3040 SwitchPos|MCI

Application: Switch-off positioning

I/O level: "MCI" control mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00008 | Original application|control source

Data type: UNSIGNED_16

Index: 24567

d

= 5FF7

h

Parameter | Name:

C00010 | AIN1: Characteristic

Data type: INTEGER_16

Index: 24565

d

= 5FF5

h

From version 04.00.00

Analog terminals

:

Signal adaptation via characteristic

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C00010/1

0.00 %

AIN1: (+y0) = min

C00010/2

0.00 %

AIN1: (+x0) = Dead band

C00010/3

0.00 %

AIN1: (-y0) = (-min)

C00010/4

0.00 %

AIN1: (-x0) = (-Dead band)

C00010/5

100.00 %

AIN1: (+ymax)

C00010/6

100.00 %

AIN1: (+xmax)

C00010/7

100.00 %

AIN1: (-ymax)

C00010/8

100.00 %

AIN1: (-xmax)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100