2introduction: parameterising the controller – Lenze 8400 StateLine User Manual

Page 39

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

39

2

Introduction: Parameterising the controller

2.4

Device access protection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of the relevant parameters for configuring the password protection:
When the password is set, the respective restriction is active if the corresponding bit has been set:

The parameter set must be saved to the device safe against mains failure to prevent password

protection configured in the device from getting lost due to mains switching.

Save parameter settings in the memory module safe against mains failure

( 32)

Parameter

Info

Lenze setting

C00506/1

PW protection internal config

0x0007

Bit 0 Only access to user menu

• The menus in the keypad are reduced.

• Only the user menu can be used to change

parameters.

Bit 1 Parameter write protection

• System blocks cannot be used to write into

write/read parameters.

Bit 2 Parameter read protection

• System blocks cannot be used to read write/read

parameters.

Bit 3 ... 15 Reserved

C00508/1

PW protection config. X6 (DIAG)

0x0006

Bit 0 Reserved

Bit 1 Parameter write protection

• The diagnostics interface X6 cannot be used to

write into write/read parameters.

Bit 2 Parameter read protection

• The diagnostics interface X6 cannot be used to

read write/read parameters.

Bit 3 ... 15 Reserved

C00509/1

PW protection config. X1 (CAN)

0x0006

Bit 0 Reserved

Bit 1 Parameter write protection

• The CANopen interface X1 cannot be used to

write into write/read parameters.

Bit 2 Parameter read protection

• The CANopen interface X1 cannot be used to read

write/read parameters.

Bit 3 ... 15 Reserved

C00510/1

PW protection config. MCI

0x0006

Bit 0 Reserved

Bit 1 Parameter write protection

• The fieldbus interface (MCI) cannot be used to

write into write/read parameters.

Bit 2 Parameter read protection

• The fieldbus interface (MCI) cannot be used to

read write/read parameters.

Bit 3 ... 15 Reserved