Parameter | Name:

C00951 | L_Interpolator_1: No. of interpolation steps

Data type: UNSIGNED_16

Index: 23624

d

= 5C48

h

From version 04.00.00

The

L_Interpolator_1

FB: No. of interpolation steps

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00952 | L_Interpolator_1: Limit value - error cycles

Data type: UNSIGNED_16

Index: 23623

d

= 5C47

h

From version 04.00.00

The

L_Interpolator_1

FB: Limit value for missing data telegrams

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 5

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00953 | L_Interpolator_1: Speed-up

Data type: UNSIGNED_8

Index: 23622

d

= 5C46

h

From version 04.00.00

FB

L_Interpolator_1

: Limitation of the number of correction increments per cycle (speed-up)

Setting range

(min. value | unit | max. value)

Lenze setting

0

100 0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00965 | Max. motor speed

Data type: UNSIGNED_16

Index: 23610

d

= 5C3A

h

From version 10.00.00

When the drive reaches the motor speed set here:

• The "Fault" error response takes place, i.e. the motor is shut down immediately.

• The error message "

oS2: Max. motor speed reached

" is entered into the logbook.

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

65000 60000 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00966 | VFC: Time const. slip comp.

Data type: UNSIGNED_16

Index: 23609

d

= 5C39

h

From version 02.00.00

Filter time constant of the slip compensation for V/f characteristic control (

VFCplus

)

• The time constant of slip compensation serves to specify the dynamics of slip compensation for V/f characteristic

control without feedback.

• The lower the selected time constant, the higher the dynamic performance of the slip compensation.

Setting range

(min. value | unit | max. value)

Lenze setting

1

ms

6000 100 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1