C02231 | ls_writeparamlist: rated motor power, C02232 | ls_writeparamlist: motor rotor resistance, C02230/1 – Lenze 8400 StateLine User Manual

Page 796: C02230/2, C02230/3, C02230/4, C02231/1, C02231/2, C02231/3, C02231/4

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02230

796

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02230

C02231

C02232

Parameter | Name:

C02230 | LS_WriteParamList: Override point of field weakening

Data type: INTEGER_16

Index: 22345

d

= 5749

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

-500

Hz

500

Subcodes

Lenze setting

Info

C02230/1

0 Hz

LS_WriteParamList

: c80_val1

C02230/2

0 Hz

LS_WriteParamList

: c80_val2

C02230/3

0 Hz

LS_WriteParamList

: c80_val3

C02230/4

0 Hz

LS_WriteParamList

: c80_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02231 | LS_WriteParamList: Rated motor power

Data type: UNSIGNED_16

Index: 22344

d

= 5748

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

kW

500.00

Subcodes

Lenze setting

Info

C02231/1

11.00 kW

LS_WriteParamList

: c81_val1

C02231/2

11.00 kW

LS_WriteParamList

: c81_val2

C02231/3

11.00 kW

LS_WriteParamList

: c81_val3

C02231/4

11.00 kW

LS_WriteParamList

: c81_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02232 | LS_WriteParamList: Motor rotor resistance

Data type: UNSIGNED_32

Index: 22343

d

= 5747

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

mOhm

200000

Subcodes

Lenze setting

Info

C02232/1

276 mOhm

LS_WriteParamList

: c82_val1

C02232/2

276 mOhm

LS_WriteParamList

: c82_val2

C02232/3

276 mOhm

LS_WriteParamList

: c82_val3

C02232/4

276 mOhm

LS_WriteParamList

: c82_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising