4device control (dctrl) – Lenze 8400 StateLine User Manual

Page 102

Advertising
background image

4

Device control (DCTRL)

4.4

Internal interfaces | "LS_DriveInterface" system block

102

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tip!
If a bus control is not wanted (e.g. in case of control via terminals):
Connect both control word inputs with the wDriveCtrl output signal of the

LS_ParFix

system block. This output signal has the fixed value "9", which corresponds to the following

assignment:

• Bit 0, SwitchOn = 1
• Bit 3, EnableOperation = 1
• All others: 0

Note!

The assignment of bits 11 ... 13 and bit 15 depends on the technology application

selected in

C00005

!

• See description of the corresponding technology application.

Bit

Name

Function

Bit 0 SwitchOn

1 ≡ Change to the "

SwitchedOn

" device status

From version 05.01.00 onwards, the following applies:

This bit must be set in

the CAN AND MCI control word in order that the drive changes to the

"

SwitchedOn

" device state after mains connection. In order to reach the

"

ReadyToSwitchOn

" state, it is sufficient to set the bit to 0 in one of the two

control words.

Up to and including version 05.00.00 the following applies:

This bit must be

set in the CAN OR MCI control word in order that the drive changes to the

"

SwitchedOn

" state after mains connection.

Bit 1 DisableVoltage

1 ≡ Inhibit inverter control (pulse inhibit)

Bit 2 SetQuickStop

Activate quick stop (QSP)

Activate/deactivate quick stop ( 81)

Bit 3 EnableOperation

1 ≡ Enable controller (RFR)

• This bit must be set in CAN AND in the MCI control word, otherwise the

controller will be inhibited.

Bit 4 ModeSpecific_1

Reserved (currently not assigned)

Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault

1 ≡ Reset fault (trip reset)

• Acknowledge error message (if the error cause has been eliminated).

Bit 8 SetHalt

1 ≡ Activate stop function

• Stop drive via stopping ramp (in preparation).

Bit 9 reserved_1

Reserved (currently not assigned)

Bit 10 reserved_2
Bit 11 LenzeSpecific_1

Assignment depends on the selected technology application

• See description of the corresponding technology application.

Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail

1 ≡ Set error (trip set)

Bit 15 LenzeSpecific_4

Assignment depends on the selected technology application

• See description of the corresponding technology application.

Advertising