5motor control (mctrl) – Lenze 8400 StateLine User Manual

Page 159

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

159

5

Motor control (MCTRL)

5.6

V/f control (VFCplus + encoder)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to adapt the slip regulator gain to the operating conditions:

1. Adapt the slip regulator gain (

C00972

) to the encoder increment according to table

[5-1]

.

2. Set controller limitation (

C00971/1

) to half the slip frequency (

2 Hz).

3. Select speed setpoint (e.g. 20 % of the rated speed).
4. Enable controller.
5. Increase the slip regulator gain (

C00972

) until the drive is semi-stable.

• This can be recognised by motor noises or "humming" of the motor or by a noise on the

actual speed signal.

6. Reduce slip regulator gain (

C00972

) until the drive runs stable again (no motor

"humming").

7. Reduce slip regulator gain (

C00972

) to approx. half the value.

• With low encoder resolutions, another reduction of the the slip regulator gain for low

speeds may be necessary (speed setpoint

0).

• We recommend to finally check the behaviour at setpoint speed = 0 and to further

reduce the slip regulator gain if irregular running occurs.

8. Increase controller limitation (

C00971/1

) again (e.g. to twice the slip frequency).

Slip regulator time constant Ti

How to set the slip regulator time constant:

1. Set controller limitation (

C00971/1

) to half the slip frequency (

2 Hz).

2. Select speed setpoint (e.g. 20 % of the rated speed).
3. Enable controller.
4. Reduce the slip regulator time constant (

C00973

) until the drive is semi-stable.

• This can be recognised by motor noise, "motor vibrations" or resonance on the actual

speed value signal.

5. Increase slip regulator time constant (

C00973

) until the drive runs stable again (no motor

"oscillation").

6. Increase the slip regulator time constant (

C00973

) to approx. twice the value.

7. Increase controller limitation (

C00971/1

) again (e.g. to twice the slip frequency).