Motor control (MCTRL)

5.13

Internal interfaces | System block "LS_MotorInterface"

254

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

nInertiaAdapt_a

C00830/96

| INT

(from version 12.00.00)

Adaptation of the moment of inertia

• This process signal can be used during the process to dynamically control the

percentage of the variable moment of inertia (e.g. a reel) set in

C00919/1

which

is to be considered for setpoint feedforward control.

• Scaling: 16384 ≡ 100 % moment of inertia - process (

C00919/1

)

bBrakeChopperOn

C00833/130

| BOOL

(from version 12.00.00)

Switch on the internal brake chopper as "brake chopper slave" (

C02866/3

= "1: Yes")

when the controller is configured

Control of multiple internal brake choppers in the DC-bus system ( 234)

TRUE Switch on internal brake chopper.

nSpeedSetValueInertia_a

C00830/97

| INT

(from version 12.00.00)

Input for differential setpoint feedforward control (torque feedforward control)

• If the selection "1: nSpeedSetValueInertia_a" is set in

C00654/1

, this process

signal can be used to preselect any input value (e.g. setpoint of the position or

process controller) for torque feedforward control.

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

bVfcEcoDisable

C00833/131

| BOOL

(from version 13.00.00)

Deactivate energy optimisation for VFCplusEco

Improving the behaviour at high dynamic load changes

FALSE Activate energy optimisation.

TRUE Deactivate energy optimisation.

Identifier

DIS code | data type

Value/meaning

bLimPosCtrlOut

BOOL

"Position controller output inside the limitation" status signal

TRUE The position controller output is internally limited

nOutputPosCtrl_a

INT

Position controller output

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

dnMotorPosAct_p

DINT

Current position of the motor shaft in [increments]

dnMotorDeltaPosAct_p

DINT

Current following error in [increments]

• Following error = Difference between set position and actual position

bLimSpeedCtrlOut

BOOL

"Speed controller or manipulating variable of the slip regulator inside the limitation"

status signal

TRUE The speed controller output is internally limited

bLimSpeedSetVal

BOOL

"Reduction or increase of the setpoint speed active" status signal

TRUE Reduction or increase of the setpoint speed by the I

max

controller is

active

wMaxMotorSpeed

C00011

| BOOL

Reference speed (

C00011

)

nOutputSpeedCtrl_a

INT

Speed controller output

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• In case of the "VFC (+encoder)" motor control, this output is the output of the slip

regulator. In this case, the scaling depends on the reference frequency (display in

C00059

):

C00059

< 650 Hz: 16384 ≡ 327.68 Hz (24000 ≡ 480.00 Hz)

C00059

> 650 Hz: 16384 ≡ 655.36 Hz (12000 ≡ 480.00 Hz)

nSpeedCtrlIAct_a

INT

Current value of speed controller integrator

• Scaling depends on the selected motor control:

• V/f control (VFCplus + encoder):

16384 ≡ 100 % reference speed (

C00011

)

• Vector control (SLVC):

16384 ≡ 100 % M

max

(

C00057

)

nEffSpeedSetValue_a

INT

Effective speed setpoint

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

Identifier

DIS code | data type

Information/possible settings