679

15

Parameter reference

15.2

Parameter list | C00411

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00411

C00412

C00413

Parameter | Name:

C00411 | L_SignalMonitor_b: Signal sources

Data type: UNSIGNED_16

Index: 24164

d

= 5E64

h

The

L_SignalMonitor_b

FB: Selection of the signal sources

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00411/1

0: Not connected

Signal source for output bOut1

C00411/2

0: Not connected

Signal source for output bOut2

C00411/3

0: Not connected

Signal source for output bOut3

C00411/4

0: Not connected

Signal source for output bOut4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00412 | L_SignalMonitor_b: Inversion

Data type: UNSIGNED_8

Index: 24163

d

= 5E63

h

The

L_SignalMonitor_b

FB: Inversion of the binary outputs

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x00 (decimal: 0)

Value is bit-coded: (= bit set)

Info

Bit 0  bOut1 inverted

Bit set = inversion active

Bit 1  bOut2 inverted
Bit 2  bOut3 inverted
Bit 3  bOut4 inverted
Bit 4 

Reserved

Bit 5 

Reserved

Bit 6 

Reserved

Bit 7 

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00413 | L_SignalMonitor_a: Offs./gain

Data type: INTEGER_16

Index: 24162

d

= 5E62

h

The

L_SignalMonitor_a

FB: Gain and offset of the analog signals

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00413/1

0.00 %

Offset for output nOut1_a

C00413/2

100.00 %

Gain for output nOut1_a

C00413/3

0.00 %

Offset for output nOut2_a

C00413/4

100.00 %

Gain for output nOut2_a

C00413/5

0.00 %

Offset for output nOut3_a

C00413/6

100.00 %

Gain for output nOut3_a

C00413/7

0.00 %

Offset for output nOut4_a

C00413/8

100.00 %

Gain for output nOut4_a

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising