4device control (dctrl) – Lenze 8400 StateLine User Manual

Page 75

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

75

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Activate device command
When an online connection has been established, simply use the »Engineer« to activate a device

command by selecting the corresponding option from the Parameters tab in

C00002/x

("0: off" or

"1: On / start").

• Alternatively, the device command can also be activated via e.g. keypad or through a master

control by writing to

C00002/x

.

• Some of the frequently used device commands (such as "Save parameter set") can also be

executed via the Toolbar icons of the »Engineer« when an online connection has been

established:

Icon

Function
Enable controller

Inhibit controller

Save parameter set (for 8400: Save all parameter sets)

Note!

Device commands that can be executed via the Toolbar of the »Engineer« always affect

the element currently selected in the Project view including all subelements!

• If no controller but a system module is selected in the Project view, the corresponding

device command will be activated in all lower-level controllers having an online

connection with the »Engineer«.

Before the desired action is carried out, a confirmation prompt appears first, asking

whether the action is really to be carried out.

Advertising