Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

41

2

Introduction: Parameterising the controller

2.4

Device access protection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Activate device personalisation
The device personalisation is activated by setting a binding ID.

How to set the binding ID:

1. Enter the desired binding ID in

C00505/2

.

• The binding ID must have a length of 4 ... 16 characters.
• The binding ID may consist of any character. However, this is not sensible.

Recommended characters are: lower case letters (a - z), upper case letters (A - Z) and

digits (0 - 9).

2. Execute "Set binding ID" device command

C00002/29

= "1: On / start"

• After successful execution, status ON is displayed in

C00505/2

.

Deactivate device personalisation/change binding ID
The device personalisation is simply deactivated by deleting the set binding ID. If you want to

change the set binding ID, first delete the set binding ID as well. Then set the new binding ID.

How to delete the binding ID:

1. Enter the set binding ID in

C00505/2

.

• If controller and memory module do not have the same binding ID, enter the binding ID

of the memory module to delete the binding ID of both components.

2. Execute "Delete binding ID" device command

C00002/30

= "1: On / start"

• After a successful deletion, status OFF is displayed in

C00505/2

.

Device commands

Before the following device commands are executed, enter the corresponding binding ID in

C00505/2

.

C00002/29

Set binding ID

Activate device personalisation

0: Off / ready

C00002/30

Delete binding ID

Deactivate device personalisation/change binding ID

0: Off / ready

Status displays

C00003

Status of the last device command

-

C00507/1

Password protection - all communication channels

• Bit coded display of the active protective functions:

-

Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection

Bit 3 ... 14 Reserved

Bit 16 Memory module binding on

Parameter

Info

Lenze setting

Highlighted in grey = display parameter