Technology applications

7.5

"GeneralPurpose" functions

388

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.5.6

Analog comparison

This function compares two analog signals and can be used e.g. to realise a trigger. The comparison

operation, hysteresis and window size can be parameterised.

[7-23] GeneralPurpose function "Analog comparison"

• For a detailed functional description see FB

L_Compare

.

7.5.7

Binary signal monitor

This function serves to output four binary signals selected from a list of all binary output signals

available in the drive controller. You can set an inversion of the output signals.

[7-24] GeneralPurpose function "Binary signal monitor"

• For a detailed functional description see FB

L_SignalMonitor_b

.

bGPCompareOut

nGPCompareIn1_a

nGPCompareIn2_a

f =

C00680

C00682

C00681

C00830/16

C00830/17

Parameter

Info

Lenze setting

Value Unit

C00680

L_Compare_1: Fct.

6: |In1| < |In2|

C00681

L_Compare_1: Hysteresis

0.50 %

C00682

L_Compare_1: Window

2.00 %

bGPSignalOut1

C00411/1

C00412 - Bit 0

0

1

C00411/2

C00411/3

C00411/4

bGPSignalOut2

C00412 - Bit 1

0

1

bGPSignalOut3

C00412 - Bit 2

0

1

bGPSignalOut4

C00412 - Bit 3

0

1

Parameter

Info

Lenze setting

Value Unit

C00411/1...4

L_SignalMonitor_b: Signal 1 ... 4

0: Not connected

C00412

L_SignalMonitor_b: Inversion

Bit coded