C00448 | digout decoupling value, C00449 | freqinxx_dnout_p, C00449/1 – Lenze 8400 StateLine User Manual

Page 686: C00448, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00448

686

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00448

C00449

Parameter | Name:

C00448 | DigOut decoupling value

Data type: UNSIGNED_16

Index: 24127

d

= 5E3F

h

From version 04.00.00

Definition of the value the digital output terminals are to have in the decoupled state.

• Bit set = HIGH level

Configuring exception handling of the output terminals

Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0000 (decimal: 0)

Value is bit-coded: (= bit set)

Bit 0  Relay_ON
Bit 1  DigOut1_ON
Bit 2 

Reserved

Bit 3 

Reserved

Bit 4 

Reserved

Bit 5 

Reserved

Bit 6 

Reserved

Bit 7 

Reserved

Bit 8 

Reserved

Bit 9 

Reserved

Bit 10 

Reserved

Bit 11 

Reserved

Bit 12 

Reserved

Bit 13 

Reserved

Bit 14 

Reserved

Bit 15 

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00449 | FreqInxx_dnOut_p

Data type: INTEGER_32

Index: 24126

d

= 5E3E

h

From version 06.00.00

Output of the encoder position of the DI1/DI2 frequency input

Display range

(min. value | unit | max. value)

-2147483647

Incr.

2147483647

Subcodes

Info

C00449/1

FreqIn12_dnOut_p

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1