C00016

C00018

Parameter | Name:

C00016 | VFC: Vmin boost

Data type: UNSIGNED_16

Index: 24559

d

= 5FEF

h

Boost of the V/f voltage characteristic in the range of small speeds or frequencies with V/f characteristic control

(

VFCplus

) and V/f control (

VFCplus+encoder

)

• This may increase the starting torque.

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.

Motor control (MCTRL)

:

Setting the Vmin boost

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 1.60 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00018 | Switching frequency

Data type: UNSIGNED_8

Index: 24557

d

= 5FED

h

Selection of the pulse width modulated switching frequency transferred from the inverter to the motor

• Select between an ideal setting for the drive which provides smooth running, and an optimal setting with regard

to the inverter which keeps its losses to a minimum (min. Pv).

• Both possibilities offer fixed and variable switching frequencies.

• When a variable switching frequency is selected, the switching frequency may change as a function of the load

and rotational frequency.

Selection of switching frequency

Selection list

(Lenze setting printed in bold)

1 4 kHz var./drive-optimised
2 8 kHz var./drive-optimised
3 16 kHz var./drive-optimised
5 2 kHz constant/drive-optimised
6 4 kHz constant/drive-optimised
7 8 kHz constant/drive-optimised
8 16 kHz constant/drive-optimised

11 4 kHz var./min. Pv
12 8 kHz var./min. Pv
13 16 kHz var./min. Pv
15 2 kHz constant/min. Pv
16 4 kHz constant/min. Pv
17 8 kHz constant/min. Pv
18 16 kHz constant/min. Pv
21 8 kHz var./drive-opt./4 kHz min
22 16 kHz var./drive-opt./4 kHz min
23 16 kHz var./drive-opt./8 kHz min
31 8 kHz var./min. Pv/4 kHz min
32 16 kHz var./min. Pv/4 kHz min
33 16 kHz var./min. Pv/8 kHz min

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1