C00323 | transmission mode can rx pdos, C00324 | can transmission blocking time, C00324/x – Lenze 8400 StateLine User Manual

Page 660: C00324/2, C00324/3, C00324/4, C00324/5, C00323/1, C00323/2, C00323/3

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00323

660

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00323

C00324

Parameter | Name:

C00323 | Transmission mode CAN Rx PDOs

Data type: UNSIGNED_8

Index: 24252

d

= 5EBC

h

RPDO transmission type according to DS301 V4.02

• In the case of the RPDO serves as monitoring setting in the case of sync-controlled PDOs.

• The following transmission modes are supported:

• 0: Synchronous and acyclic

• 1 ... 240: Synchronous and cyclic

• 252: Synchronous - RTR only

• 253: Asynchronous - RTR only

• 254: Asynchronous - manufacturer-specific

• 255: Asynchronous - device-profile specific

• The basic setting for all PDOs is "Asynchronous - manufacturer-specific" (254).

• Illustration of the CANopen objects

I-1400/2

...

I-1403/2

(see DS301 V4.02).

System bus "CAN on board"

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C00323/1

254

Transmission mode CAN1 IN

C00323/2

254

Transmission mode CAN2 IN

C00323/3

254

Transmission mode CAN3 IN

C00323/4

254

Transmission mode CAN4 IN

From version 15.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00324 | CAN transmission blocking time

Data type: UNSIGNED_16

Index: 24251

d

= 5EBB

h

From version 06.00.00

Blocking time for the transmission of the emergency telegram and the process data

Note:

If the "Asynchronous - manufacturer-specific/device profile-specific" transmisson type is set, the transmission cycle

timer is reset to 0 if event-controlled transmission has been triggered.

Example: Cycle time (

C00356/x

) = 500 ms, blocking time = 100 ms, data change sporadically:

• In the case of a sporadic data change < 500 ms, due to the blocking time set, transmission takes place every

100 ms (event-controlled transmission) as quickly as possible.

• In the case of a sporadic data change > 500 ms, due to the cycle time set, transmission takes place every 500 ms

(cyclic transmission).

System bus "CAN on board"

Setting range

(min. value | unit | max. value)

0

ms

6500

Subcodes

Lenze setting

Info

C00324/1

0 ms

CAN emergency blocking time

C00324/2

0 ms

CAN1_OUT blocking time

C00324/3

0 ms

CAN2_OUT blocking time

C00324/4

0 ms

CAN3_OUT blocking time

C00324/5

0 ms

CAN4_OUT blocking time

From version 15.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1