2introduction: parameterising the controller – Lenze 8400 StateLine User Manual

Page 29

Advertising
background image

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

29

2

Introduction: Parameterising the controller

2.3

General notes on parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Menu structure
In the keypad, the parameters are classified into various menus and submenus.

• The USER menu includes a selection of frequently used parameters.
• The Code list contains all parameters.
• The Go to param function enables you to reach the corresponding parameter directly.
• The Logbook logs all errors and their chronological history.
• The Diagnostics menu contains diagnostic/display parameters for displaying device-internal

process factors, current actual values and status messages.

Userlevel

From version 12.00.00 onwards

, the extent of menus, submenus an codes shown in the keypad can

be adapted by selecting the "Userlevel" in

C00001/1

:

• Userlevel Standard (Lenze setting): Only the most important menus and codes are shown in the

keypad.

• Userlevel Expert: All menus and codes are shown in the keypad.
• Userlevel Service: For service purposes only (Lenze service).

The the Userlevel has been changed, the menus are restructured in the keypad according to the

selected Userlevel. The parameters of a plugged in communication module are always displayed

completely independent of the set Userlevel.

Function - left function key

Function - right function key

Change parameter setting

(change to editing mode)

Accept change in the controller

(no saving with mains failure protection 

)

Back to main menu

Abort (discard change)

Parameter can only be changed when the controller is inhibited

Save all parameter settings in the memory module safe against mains failure

Control elements

Execute the function assigned to the function key (see LCD display)

Execute the stop function set in

C00469

(Lenze setting: Inhibit controller)

Deactivate stop function again (Lenze setting: Enable controller again)

In the menu level: Select menu/submenu

In the parameter level: Select parameter

In the editing mode: Change marked digits or select list entry

In the menu level: Select submenu/change to parameter level

In the editing mode: Cursor to the right

In the menu level: One menu level higher (if available)

In the parameter level: Back to the menu level

In the editing mode: Cursor to the left

LCD display