7technology applications – Lenze 8400 StateLine User Manual

Page 306

Advertising
background image

7

Technology applications

7.2

TA "Actuating drive speed"

306

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

GP: GeneralPurpose

The following inputs are interconnected with logic/arithmetic functions on application level for free usage.

"GeneralPurpose" functions

bGPFree1 ... bGPFree2

BOOL

(from version 11.00.00)

Free inputs for digital signals

• Digital signals can be transferred from the I/O level to the application level via

these inputs.

nGPAnalogSwitchIn1_a

nGPAnalogSwitchIn2_a

INT

Analog switch

: Input signals

• The input signal selected via the selection input bGPAnalogSwitchSet is output at

output nGPAnalogSwitchOut_a.

bGPAnalogSwitchSet

BOOL

Analog switch

: Selection input

FALSE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn1_a

TRUE nGPAnalogSwitchOut_a = nGPAnalogSwitchIn2_a

nGPArithmetikIn1_a

nGPArithmetikIn2_a

INT

Arithmetic

: Input signals

• The arithmetic function is selected in

C00338

.

• The result is output at output nGPArithmetikOut_a.

nGPMulDivIn_a

INT

Multiplication/Division

: Input signal

• The factor for the multiplication can be set in

C00699/1

(numerator) and

C00699/2

(denominator).

• The result is output at output nGPMulDivOut_a.

bGPDigitalDelayIn

BOOL

Binary delay element

: Input signal

• The on-delay can be set in

C00720/1

.

• The off-delay can be set in

C00720/2

.

• The time-delayed input signal is output at output bGPDigitalDelayOut.

bGPLogicIn1

bGPLogicIn2

bGPLogicIn3

BOOL

Binary logic

: Input signals

• The logic operation is selected in

C00820

.

• The result is output at output bGPLogicOut.

nGPCompareIn1_a

nGPCompareIn2_a

INT

Analog comparison

: Input signals

• The comparison operation is selected in

C00680

.

• Hysteresis and window size can be set in

C00680

and

C00682

.

• If the comparison statement is true, the output bGPCompareOut will be set to

TRUE.

bGPDFlipFlop_InD

bGPDFlipFlop_InClk

bGPDFlipFlop_InClr

BOOL

D-FlipFlop

: Input signals

• Data, clock and reset input

Free inputs

The following inputs can freely be interconnected on the application level.

The signals can be transferred from the I/O level to the application level via these inputs.
bFreeIn1 ... bFreeIn8

BOOL

Free inputs for digital signals

wFreeIn1 ... wFreeIn4

WORD

Free inputs for 16-bit signals

Identifier

Data type

Information/possible settings

Advertising